Key Benefits
|
||||
About the GW6 valve core - how odours are prevented The replaceable core (product: GW6V) of GW6 urinals feature:
|
||||
How to prevent blockages in waterless urinal waste runs Gentworks recommends dosing/sluicing urinals fitted with the GW6 valve, approximately once every 2 to 4 weeks, with a solution of Bactericidal Cleaner mixed with warm water from the washroom hot tap, All urinals are prone to blockages, whether waterless or not. The advantage of waterless urinals over flushed urinals is that there is no limescale from water to combine with urine to form a hard scale. Nevertheless, uric acid crystals and sludge can form, particularly where debris and hair has fallen into the waste pipes and the flow of urine alone has not been able to flush such obstructions away to the main drain. In a washroom with new waste pipes configured perfectly, the flow of urine itself can be sufficient to keep the pipework clear. However, a simple act of preventative maintenance such as dosing/sluicing with Bactericidal Cleaner dramatically reduces the chance of a blockage in all cases. Gentworks recommends regular dosing/sluicing for all our waterless urinal systems that do not use a liquid seal. For waterless urinals with a liquid seal, sluicing could break the seal and is therefore only recommended during servicing or a cartridge change. |
||||